FEATURES
■ Handy EDM Head
■ Complete Application Programs
■ Extended Internal Memory (Max. 17000 Points)
■ Convenient Data Management System
■ Superior Waterproof & Dustproof Capabilities
■ Min. Reading 0.1mm
Distance measurement (visible laser)
- Type …………… red laser
- carrier wave …………… 0.670μm
- Measuring system …………… Basic frequency 60MHZ
- EDMtype …………… coaxial
- Display (least count) …………… 1mm
- Laser facula …………… approx.7×14㎜ / 20m(reflectorless mode only)
approx.10×20㎜ / 50m
- Accuracy
With reflector:
| EDM measuring program | Accuracy Standard deviation | Time per measurement |
| fine | 2㎜+2ppm | <1.8s |
| fast | 3㎜+2ppm | <1.2s |
| tracking | 5㎜+2ppm | <0.8s |
| IR-tape | 5㎜+2ppm | <1.2s |
Without reflector:
| EDM measuring program | Accuracy Standard deviation | Time per measurement |
| Reflectorless fine | 5+2ppm | <1.2s |
| Reflectorless tracking | 10+2ppm | <0.8s |
h.Range
With reflector
| Atmospheric conditions | Standard prism | Reflector tape |
| 5km(Haze) | 1000m | 300m |
| 20km(Good weather) | 5000m | 800m |
Without reflector
| Atmospheric conditions | No reflector(white target)※ | No reflector (grey,0.18) |
| Object in strong sunlight, severe heat shimmer | 160m | 100m |
| Object in shade, or sky overcast | 200m | 120m |
Kodak Grey Card used with exposure meter for reflected light
Other Specification
| Display | Max:999999.999m Min:0.1mm |
| Unit | m/ft Selectable |
| Average measuring times | The average value of2~255 times |
| Meteorologic Correction | Manual input, Auto correction |
| Atmospheric refraction and earth curvature correction | Manual input, Auto correction K=0.14/0.2 Selectable |
| Reflection prism correction | Manual input, Auto correction |
Telescope
Image Erect
Magnification 30×
Effective aperture 45mm (EDM 48mm)
Resolving power 4″
Field of view 1°30′
Minimum focus 1m
Stadia ratio 100
Sight distance precision ≤0.4%D
Tube length 154mm
Angle Measurement
Measuring method Photoelectric detection by incremental encoder
Dia of circle (vertical, horizontal) 79mm
Minimum reading 1″/5″Selectable
Detection method Horizontal: Dual
Vertical :Dual
Measuring unit 360°/400gon/6400mil Selectable
Vertical angle0° Zenith0°/Horizontal0°Selectable
Accuracy NTS-352R:2″
NTS-355R:5″
Vial
Plate vial 30″/2mm
Circular vial 8′/2mm
Vertical Compensator
System Liquid-electric detection/plate vial
Compensation range ±3′
Resolving power 1″
Optical Plummet
Image Erect
Magnification 3×
Focusing range 0.5m~∝
Field of view 5°
Display
Type LCD,Four lines,digital
Data Communication
Port RS-232C
On-board Battery
Power resource Rechargeable Ni-H battery
Voltage DC6V
Type of battery NB-20B Battery
NB—20C Battery (Selectable)
Continuous operation time NB-20B 8hrs
NB—20C 12hrs
Operation Environment
Operating temperature -20°~+45℃
Size & weight
Dimension 160×150×330mm
Weight (Exclude Battery) 5.2kg